Roof Anchor Posts Roof safety anchor tie off posts for workers Counterweight Anchor System Portable rooftop anchor system Reusable Roof Anchors High quality anchor options provide effective roofing fall protection Steel Beam Anchors Adjustable beam anchors allow for efficient stationary or mobile use
These U bolt anchors install into wood roof frames to provide a permanent tie off point for personal fall protection equipment The adjustable U bolt anchor fit a range of framing sizes It penetrates through the roof and is secured around the wood framing The attachment point protrudes from the roof and has a protective cover Permanent anchors provide a convenient
Anchor points are a vital part of a fall protection system Anchor points are usually installed on the roof but can also be installed on doors and windows Roof anchor points are used to connect lanyards lifelines and other forms of tie off which prevent a worker from falling Roof anchors can be as simple as a D ring connection or as complex as a complete lifeline system
Commonly used in conjunction with tie off point such as an I beam column rebar scaffolding roof truss or other structural member Anchorage connector used to join connecting device to anchor point when direct connection does not exist Anchorages and connectors must be easily accessible capable of supporting 5 000 lbs of force per worker and must be located high
Featured anchors 3M™ DBI SALA 174 Glyder™ Sliding Beam Anchor Provides complete horizontal mobility on I beams overhead attachments or at your feet 3M™ DBI SALA 174 Web Tie Off Adaptor Pass through design 4 4 cm 1 3 4
Versatile single point anchor adapts to a wide range of roof designs With a variety of models available the Miller Fusion Roof Anchor Post can accommodate most industrial roof designs including standing seam membrane built up metal sheathing concrete and wood Attaches to the surface of existing roof structures Quick easy installation reduces cost requiring minimal
The freestanding counterweight anchor provides a tie off point for personnel performing work on flat roofs or structures It is non penetrating to eliminate damage to the working surface and is assembled using sixteen separate easy to carry counterweights allowing the user to never have to lift more than 45 pounds while installing the anchor 3M DBI SALA Freestanding
Permanent anchors provide a convenient tie off point when roof access or maintenance is required on a regular basis Anchors should always be inspected and replaced after being exposed to a fall Brands Permanent Anchors for Concrete Metal amp Wood Roofs Purchased products These anchors permanently attach to compatible wood concrete or metal roofs to
3M™ DBI SALA 174 Permanent Roof Anchor 2104540 with detachable D ring silver 3 6 in x 3 2 in x 9 8 in 9 1 cm x 8 2 cm x 25 cm 3M™ DBI SALA 174 Drop Thru Anchor 2104819 silver 2 ft 0 6 m 3M™ DBI SALA 174 Web Tie Off Adaptor 1002106 adjustable yellow 6 ft 1 8 m 3M™ DBI SALA 174 Drop Thru Anchor 2104816 silver 10 ft 3 0 m 3M™ DBI SALA 174 Web Scaffold
The RetroFit is designed to give all who access the roof a reliable tie off point Installs with just 8 nails and comes with special butyl waterproof flashing strips to seal the stainless steel nails Fabricated with 430 stainless steel and certified for over 5 000 pounds Installs under Vented amp Non Vented Ridge Caps
What good is an anchor point that can hold 5000 lbs when it will shear off your wall or building far before reaching its capacity A 5000 lbs anchor point may not be required according to OSHA By misinterpreting the OSHA ruling on anchor points you are significantly limiting yourself in areas that are already lacking options
buildings have roof anchor points to tie off scaffolding or swing stages and other anchor points for fall protection of workers The requirements of the Occupational Health and Safety Code are very specific with respect to design of life safety tie offs The OHS Code is silent with respect to requirements for inspection and maintenance of roof anchors The OHS Code defers to the
WorkHorse fall protection Roof Anchor can be used on most wood composition roof tops The anchor is temporary reusable and fits up to a 12 12 roof pitch 5000 lb rated anchor Easy installation Durable zinc plated steel 10 fasteners included 9cm in length Capacity 310 lbs including tools and equipment Specifications Specifications Dimensions Assembled Depth
MSA Workman R Reusable Roof Anchor Center holes are offset to reduce the possibility of the truss splitting during installation Can be used off roof peak in a flat position Fits any wooden roof up to 12 12 pitch 400 pound maximum worker capacity MSA
A single point anchor may be designed for single or dual tie off as long as each user attaches to a designated D Ring Multiple users should never tie off to the same D Ring under any circumstances Rooftop single point anchors can be used in conjunction with a variety of deck substrates including metal standing seam rubber membrane or concrete Single point
Tie back anchors are easy to understand and use resulting in increased worker productivity Strength amp Durability Our Tieback Anchors feature a hot dipped galvanized steel exterior and are Cal OSHA compliant resisting up to 5 400 lbf 24kN in any direction without fracture or pullout and 2 500 lbf 11 1kN without any permanent deformation Insulated Posts All
roof anchors and tie off to them along the way Here are some examples on the right On newer homes some builders leave a hole in the sheathing near the roof peak so that you can tie off inside the house Depending on the size of the roof you may have to install several temporary anchors before you reach the roof peak Ensure that your anchors are installed
For rooftop settings Weighted Base Single Point Anchors provide free standing tie off points eliminating the need to attach to the roof surface Portable Single Point Anchors for construction applications may attach to structural steel window and door jams or concrete parapet walls Cost effective and easy to install Portable Single Point Anchors provide
As an essential element of a fall protection system anchor points are normally installed on the roof I beams columns rebars scaffolding or other structural areas and are used to connect lanyards lifelines and other tie offs to prevent the worker from falling They can be as simple as a D ring connection or as complicated as a complete lifeline system Anchors are offered as
pODTR uC OvERviEw The RoofSafe™ Anchor and Cable System is a horizontal lifeline system that allows continuous uninterrupted access to all areas of a roof It can span up to 40 ft 12m between anchors and provides continuous hands free versatility for
Mobile tie off point that provides fall protection for two people Fall arrest for one and fall restraint for one Non penetrating design protects the roof s integrity Quick easy assembly Meets OSHA requirement 1926 502 d 15 and 16
Choosing the right anchor point can be difficult The main criteria most people look for when shopping for an anchor point is that it will withstand a 5000 lbs load Though that is the main selling feature on some anchor points there are times when your attachment may fail
NATIONAL SAFETY INC is certified as a Small Contractor and Supplier SCS firm SCS ID 275
Permanent or Temporary application Direct tie off or horizontal lifeline designed by a qualified person Stock finish clear zinc electroplate Weld or Weld Bolt base to structural steel Weld Bolt base epoxy to concrete Pipe base stock 20 quot tall 26 quot to top of tie off plate Custom finishes available to match roof Custom Anchors for scaffold Call 800 301 3188 for assistance to
These U bolt anchors install into wood roof frames to provide a permanent tie off point for personal fall protection equipment The adjustable U bolt anchor fit a range of framing sizes It penetrates through the roof and is secured around the wood framing The attachment point protrudes from the roof and has a protective cover
2021 05 11 nbsp 0183 32 Deadweight anchors provide an anchor point on roofs when fixed anchors are not preferred and users want a fall restraint or arrest option in a single area These anchors work best for longer term jobs that require access to a specific area on a roof Most deadweight anchors provide mobility but some styles offer easier movement than others They often work
Anchor Layout Requirements 1 Anchors shall be identified on a plan of maintenance typically posted on the inside of the roof door so that workers can easily locate these anchorages on roofs 2 Each worker shall be tied off to two independent anchorages – one for a fall arrest rope and one for a suspension rope 3
Tie off to anchors on the roof such as ridge brackets or straps If there are no anchors install them before starting work When moving from one anchor point to another always tie off to the next one before unhooking from the previous one This ensures fall protection at all times To minimize acceleration and avoid striking the ground below in case of a fall limit the amount of
This anchor gives everyone who accesses the roof a reliable tie off point without lasting damage to your rooftop These anchor points are easily installed using 8 16d nails not included The Adjustable Pitch Roof Anchor is designed for reroofing remodeling and new construction Key Features Easily bends over the peak of the roof Lightweight Easy to install Max user capacity