2018 11 17 nbsp 0183 32 I ll bet that when that pole and guy wire was put in it wasn t crossing a driveway 11 16 2018 08 57 AM 3 budwad View Profile View Forum Posts Private Message Senior Member Join Date Nov 2013 Posts 7 056 Re Utility Pole Guy Wire Whether or not the electric company can charge you for relocating a pole would be found in what is called the tariffs That
E GUY ANCHORS Two basic types of anchoring systems are used for downguys one is the screw type and the other is the Manta Ray type The screw anchors come in two different styles a single helix and a multi or double helix The single helix anchor is 8 feet long with a 10 diameter screw The multi helix anchor is 5 feet long and
Utility Measurement Systems Line Post Sensors Sidewalk Guy End Fitting with one clamp Used where space is not available for standard guying Use with No 0501 Pole End Fitting and 2 quot diameter pipe Not included Hot dip galvanized RUS Listed Compare View Details Resource Quick View FITTING GUY SIDEWALK By CHANCE Utility Catalog ID 0501 Sidewalk
Our guy wire kit for a 25ft utility pole includes the 6ft anchor rod insulator guy wraps thimbleye bolt square washer guy anchor and guy line Guy Wire Line Kit with 6ft Anchor Rod for 25ft Pole Close Lumber from Close Lumber and Corning Lumber Shop online and your local store for all your building materials lumber hardware tools and more
Towers Utility Poles Customers looking for strong heavy duty guying anchors for towers and poles choose American Earth Anchors Penetrators Bullets and Arrowheads Great for securing telephone and power poles ziplines communication equipment and more Our Penetrator anchors screw easily into the ground in clay or sandy soil
Utility pole guy wire Note A guy wire is usually used with a guy set which is insulated to avoid electric shock if any person touches it For telecommunications and broadcasting Guy wires used to support the telephone pole or antenna mast are about the same as they are for the power system guy wires for telecommunications and broadcasting Be clear that NEVER install a
Utility Poles Guy Wires Pole Topping Damaged Replacements Difficult Location Jobs Utility Pole Maintenance Pole to pole or building to pole we can get the work done quick for you Aerial electrical services cabling installations and guy wire supporting From high voltage to LV communication we are the utility pole experts Ask us about utility company requirements
My guess would be the Public Utility has a Right of way for ONE pole and if that pole was placed 35 years ago and the original guy wire then as well then the right of way has already been defined by latin word for if it has been going on for 10 years it is the way Charter Cable came after the fact way after the fact and on a pole they only RENT USAGE of and put in a second
A come a long is conveniently attached to the lifting eye and to the guy wire and the guy tensioned to remove the slack A preformed helical wire wrap is inserted through the eye on the top end and assembled onto the guy wire Contact Refer to our Utility Anchors Catalog for additional information or contact one of our local MacLean Power Distributor that can be
E GUY ANCHORS Two basic types of anchoring systems are used for downguys one is the screw type and the other is the Manta Ray type The screw anchors come in two different styles a single helix and a multi or double helix The single helix anchor is 8 feet long with a 10 diameter screw
2020 03 07 nbsp 0183 32 Re Removing a utility pole guide wire anchor Attach a chain to it Attach chain to FEL Pull the FEL up till its tight then take a crowbar and turn the post out You might have to adjust the FEL upwards as you do it If thats to much work dig down a foot and cut it off
2011 09 10 nbsp 0183 32 A No 9 Tri Anchor pole mount system was used to secure the temporary wooden poles to the ground Galbraith Power BC Inc installed two guy wires on each of the two temporary poles and a bridal guy wire between the two poles to provide structural stability 5 1 3 The No 9 Tri Anchor pole mount system was designed to be used in solid rock The
2018 03 04 nbsp 0183 32 If there is a utility easement there is nothing you can do about it If there is NO utility easement you need to contact Verizon and tell them that they need to move it DO NOT cut the wire or you could be liable for damaging property and sued or arrested 20yrsinBranson 06 13 2012 06 07 PM DawnSells 654 posts read 1 967 654 times
2021 09 14 nbsp 0183 32 Anchor Rods Guy Wire Anchor Rod For Utility Pole Jinyong Anchor Shaft Protection Systems Great Plains Tower Anchor Guy Adapters Pulling
Our guy wire kit for a 30ft utility pole includes the 6ft anchor rod insulator guy wraps thimbleye bolt square washer guy anchor and guy line Guy Wire Line Kit with 6ft Anchor Rod for 30ft Pole Close Lumber from Close Lumber and Corning Lumber Shop online and your local store for all your building materials lumber hardware tools and more
2003 08 11 nbsp 0183 32 I have removed a couple of these anchors by unscrewing them The end of the rod is screwed into the anchor by turning counter clockwise you will unscrew it and be able to pull the rod out of the ground The ones I have removed were 8 feet long Mike Aug 11 2003 5 H Hoeman00 Platinum Member Joined Jun 29 2002 Messages 873 Location N Central Ohio
2006 05 01 nbsp 0183 32 There is probably no way for them to move just the guy wire The pole will have to be relocated That will probably mean rerouting the utility Not something they are likely to do just on your whim Be careful mowing around your guy wire especially if
Popular uses include antenna telephone pole and utility pole jobs it will do well in almost any situation that requires high strength and high tension EHS Wire Specifications Our guy wire is all EHS Extra High Strength It s also all galvanized which provides protection from the elements over time This cable is available in two configurations 1x7 sizes range from 1 4 up to 5 8
2021 02 10 nbsp 0183 32 A guy wire is a stabilizing brace used to secure or steady a sign or structure It can be made of rope wire or cable One end of the wire is attached to the structure or sign and the other end is anchored at a distance to a stable ground object through tension These wires are commonly used to brace tents ship and radio masts utility poles
Guy Wire Guy wire also known as stay wire and a messenger wire is used on the overhead line construction purposes The guy wire is assembled with a guy thimble pole bracket stay rod and a turnbuckle stay set for performance These accessories needed for the execution are with an aim to stabilize the pole and the rest of the conductors for optimum performance
2014 04 30 nbsp 0183 32 This will draw the overhead line the power pole symbol the guy anchor symbol and the guy cable to the correct power pole At some point between the Power Pole shots take a shot for your overhead utility types directly under the line quot 5E 4C quot This will keep track of your wire counts and allow you to place a label on the overhead line
2016 06 15 nbsp 0183 32 Our utility company planted a guy wire approx 20 ft into our back yard to support a utility pole that was leaning in the alley behind our property without contacting us This was done six days ago and I contacted them on the same day with a complaint I have contacted local maps and records and they searched the deeds and found no easements recorded for the property
2018 01 16 nbsp 0183 32 Civil utility pole with guy wires Couldn t believe there wasn t a utility pole block yet so here we go A simple pole default visibility with no guy wires and options to turn on a single or double guy wire with polar stretch to locate the guy s anchor point edit modified per remarks Thank you as well as made annotative and fixed the size
2020 06 04 nbsp 0183 32 Pole structure means a main support for a line and consists of one or more poles plus any guys anchors before any conductors are attached to the pole and located so that the guy will not be abraded by rubbing against any wire pole or structure A guy located where there is possibility of contact with supply conductors due to the failure of the guy or
2010 04 12 nbsp 0183 32 I had a guy wire from an street light pole attached to a tree on my property that I had removed When the tree was removed in October 2009 the guy wire was detached I called the electric company to advise them of the removal and they advised me that a new guy wire had to be attached for safety
Used for guying wires at utility poles Anchors are installed by simply turning anchor into ground No Wrench Anchors may be driven by hand or with power equipment Eye dimensions are the same as Anchor Rods Screw anchors consist of an unthreaded triple eye rod with an angled point and a firmly welded helix
Poleline Hardware 215 Products Anchors 8 Bolts Nuts amp Washers 33 Brackets 2 Clamps amp Clevises 20 Guy Guards Grips amp Fittings 20 Guy amp
An electric utility worker wants to anchor a guy wire from the top of a 20 4 foot utility pole to a spot that is 8 5 feet from the base of the pole on level ground How long does the guy wire need to be Round your answer to one decimal place ensley84 is waiting for your help Add your answer and earn points New questions in Mathematics please help me please An electric
EMC Guy Markers Guy Guards are made of high impact UV stabilized plastic and provides durable high impact economical protection for exposed utility pole guy wires dead end fittings and anchor rods In addition our Guy Markers are used on towers that utilize guy wires such as cell phone towers or other communication towers
2012 01 01 nbsp 0183 32 The city s original plan was to install an unsightly span guy pole on the other side of the street and relocate the anchors and guy wires This was unpopular and the utility turned to Duratel for a solution Duratel s 14 inch pole profile allowed them to eliminate all the anchors and down guys and delete the installation of an additional pole across a two lane street reducing